The Aldehyde Assay quantitatively determines the presence of aldehydes in urine specimens submitted for DAU Testing. This assay is for use on automated chemistry analyzers. The presence of some aldehy...
The Aldehyde reagent reacts with an aldehyde functional group to produce a color proportional to the aldehyde concentration in the test sample, and is measured via a spectrophotometer.
Stability...
ID:
G-2000 |
Size:
500 mL each |
ID:
G-2070/250 |
Size:
250 mL each |
ID:
G-2070/100 |
Size:
100 mL each |
Aldehyde Calibrator 100 mg/L is a standard solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted on bottl...
The Creatinine Assay Kit quantitatively determines the creatinine level of urine specimens submitted for DAU testing. This assay is for use on automated chemistry analyzers. According to SAMHSA a urin...
The Creatinine Assay Kit quantitatively determines the creatinine level of urine specimens submitted for DAU testing. This assay is for use on automated chemistry analyzers. According to SAMHSA a uri...
The Creatinine reagent quantitatively determines creatinine values in urine using a modified Jaffe method in which the analyte reacts with hydroxide and picric acid to yield a colored complex read spe...
ID:
C-1250 |
Size:
950 mL each |
ID:
C-1270/450 |
Size:
450 mL |
ID:
C-1270/100 |
Size:
100 mL |
Creatinine Calibrator 2 mg/dL is a standard solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted on bot...
Creatinine Calibrator 5 mg/dL is a standard solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted on bott...
Creatinine Calibrator 20 mg/dL is a standard solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted on b...
Creatinine Calibrator 100 mg/dL is a standard solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted on ...
Creatinine Calibrator 200 mg/dL is a standard solution for calibrating the assay.
Stability and Storage: Unopened bottles are stable until expiration date noted on bottle when stored at 2-100 ...
Creatinine Calibrator 300 mg/dL is a standard solution for calibrating the assay.
Stability and Storage: Unopened bottles are stable until expiration date noted on bottle when stored at 2-100 C. ...
Creatinine Calibrator 400 mg/dL is a standard solution for calibrating the assay.
Stability and Storage: Unopened bottles are stable until expiration date noted on bottle when stored at 2-100 C...
Creatinine Calibrator 500 mg/dL is a standard solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted on ...
Creatinine Calibrator 600 mg/dL is a standard solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted on b...
Zero Calibrator 0 mg/L is a standard solution for calibrating the Aldehyde, Chromate, Creatinine, Nitrite, and Oxidant assays to meet SAMHSA requirements.
Stability and Storage: Unopened bottl...
The Creatinine Extended Range Assay quantitatively determines the creatinine concentration in urine samples. This assay is for use on automated chemistry analyzers. The assay exhibits a linear range ...
The Creatinine Extended Range R1 & R2 Reagents quantitatively determine the creatinine concentration in urine samples. This assay is for use on automated chemistry analyzers. The assay exhibits a lin...
ID:
C-1250E |
Size:
950 mL each |
Creatinine Extended Range Calibrator 400 mg/dL is a standard solution for calibrating the extended range assay.
Stability and Storage: Unopened bottles are stable until expiration date noted on...
The Chromate Assay Kit detects the presence of chromate added to urine specimens submitted for DAU testing. This assay is for use on automated chemistry analyzers. According to SAMHSA a urine specime...
The Chromate reagent contains a diazonium salt, which yields a colored complex read spectrophotometrically at a wavelength of 546 nm when mixed with chromate (Cr VI) in urine samples. The color inte...
ID:
M-1150L |
Size:
1,000 mL |
ID:
M-1170/500 |
Size:
500 mL |
ID:
M-1170/100 |
Size:
100 mL |
Chromate Calibrator 50 mg/L is a standard solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted on bottl...
The Nitrite Assay Kit detects nitrite added to urine specimens submitted for DAU testing. This assay is for use on automated chemistry analyzers. According to SAMHSA a urine specimen is defined as be...
The Nitrite reagent contains benzyl-substituted salt that reacts with nitrite in the urine specimen to yield a colored complex read at a wavelength of 410-415 nm. The color intensity is proportional ...
ID:
N-1010L |
Size:
1,000 mL |
ID:
N-1070/500 |
Size:
500 mL |
ID:
N-1070/100 |
Size:
100 mL |
Nitrite Calibrator 125mg/L is a standard solution for calibrating the assay to meet SAMHSA requirements....
Nitrite Calibrator 200 mg/L is a standard solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted on bottl...
Kit contains Nitrite Calibrator 500 mg/L and Zero Calibrator which are standard solutions for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stab...
Nitrite Calibrator 250 mg/L is a standard solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted on bottle w...
Nitrite Calibrator 500 mg/L is a standard solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted on bottle w...
Nitrite Calibrator 1000 mg/L is a standard solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted on bott...
Nitrite Calibrator 10,000 mg/L is a standard solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted on bo...
The Oxidant Assay Kit detects the presence of oxidants added to urine specimens submitted for DAU testing. This assay is for use on automated chemistry analyzers. This Oxidant reagent contains a redu...
The Oxidant Assay Kit detects the presence of oxidants added to urine specimens submitted for DAU testing. This assay is for use on automated chemistry analyzers. This Oxidant reagent contains a redu...
The Oxidant Assay detects the presence of oxidants added to urine specimens submitted for DAU testing. This assay is for use on automated chemistry analyzers. The Oxidant reagent contains a reducing ...
ID:
O-1351 |
Size:
500 mL each |
ID:
O-1351L |
Size:
1000 mL each |
ID:
O-1371/250 |
Size:
250 mL each |
ID:
O-1371/100 |
Size:
100 mL each |
The Oxidant Calibrator 150 mg/L is a Nitrite standard solution for calibrating the assay.
Stability and Storage: Unopened bottles are stable until expiration date noted on bottle when stored at...
Kit contains Zero and Oxidant Calibrator 150 mg/L and is a standard Nitrite solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable ...
The Oxidant Calibrator 200 mg/L is a standard Nitrite solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date n...
Kit contains Zero and Oxidant Calibrator 200 mg/L and is a standard Nitrite solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable ...
The Oxidant Validation Kit includes five oxidants identified in commercially available adulteration products. The kit enables the user to establish performance criteria for each analyte (i.e. positive...
ID:
VK-1360 |
Size:
25 mL each |
Neutual pH Buffer Wash is used to prevent contamination of a reagent by the previously pipetted reagent on automated analyzers. Cross contamination can occur when the preceding reagent is strongly ac...
The pH Assay Kit determines the pH of urine specimens submitted for DAU testing. This assay is for use on automated chemistry analyzers. According to SAMHSA a urine specimen is defined as being ADULT...
The pH R1 Reagent contains indicators that react with the urine specimen to yield a change in absorbance (based on the hydrogen ion concentration), which is read spectrophotometrically at a wavelength...
ID:
P-1070/450 |
Size:
450 mL |
ID:
P-1070/100 |
Size:
100 mL |
The pH R1 Reagent contains indicators that react with the urine specimen to yield a change in absorbance (based on the hydrogen ion concentration), which is read spectrophotometrically at a wavelength...
ID:
P1070/450N |
Size:
450 mL |
ID:
P1070/100N |
Size:
100 mL |
pH Calibrator 3.0 is a standard solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted on bottle when sto...
pH Calibrator 3.0 is a standard solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted on bottle when stor...
pH Calibrator 4.0 is a standard solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted on bottle when stor...
pH Calibrator 4.5 is a standard solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted on bottle when sto...
pH Calibrator 3.0 is a standard solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted on bottle when stor...
pH Calibrator 11.0 is a standard solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted on bottle when st...
pH Calibrator 9.0 is a standard solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted on bottle when sto...
pH Calibrator 9.0 is a standard solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted on bottle when stor...
pH Calibrator 11.0 is a standard solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted on bottle when sto...
The Specific Gravity Assay Kit determines the specific gravity of urine specimens submitted for DAU testing. This assay is for use on automated chemistry analyzers. According to SAMHSA a urine specim...
The Specific Gravity R1 Reagent contains indicators that react with the urine specimen to yield a colored complex measured at a wavelength of 600 nm. The absorbance obtained directly corresponds to th...
ID:
S-1170/450 |
Size:
450 mL |
ID:
S-1170/100 |
Size:
100 mL |
Specific Gravity Calibrator 1.001 is a standard solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted o...
Specific Gravity Calibrator 1.020 is a standard solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted on...
The Synthetic Urine Assay will detect 30 of the 30 commercially available synthetic urine products when used in combination with Axiom's Specific Gravity and pH assays. This assay is for use on automa...
ID:
SU1870/450 |
Size:
450 mL Each |
ID:
SU1870/100 |
Size:
100 mL Each |
Zero Calibrator 0 mg/L is a standard solution for calibrating the Synthetic Urine assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted...
Synthetic Urine Calibrator 100 is a standard solution for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted on bottl...
Synthetic Urine Calibrator 100 & 0 are standard solutions for calibrating the assay to meet SAMHSA requirements.
Stability and Storage: Unopened bottles are stable until expiration date noted on b...
ID:
SU-1873K |
Size: